Results from BSRIA Test Data to BSEN 442-1
@ Flow rate: 56g/sec
* All test data based on powder coated white finish RAL 9010 to BS-EN 12206-1
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 159 | 149 | 142 | 104 | 88 | 73 | 59 | 46 |
BTU/m | 542 | 506 | 484 | 355 | 300 | 249 | 201 | 157 |
BTU/ft | 164 | 153 | 139 | 106 | 91 | 75 | 60 | 45 |
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 160 | 150 | 143 | 105 | 89 | 74 | 59 | 47 |
BTU/m | 546 | 512 | 491 | 358 | 304 | 252 | 205 | 160 |
BTU/ft | 165 | 155 | 149 | 108 | 92 | 76 | 62 | 48 |
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 181 | 170 | 162 | 119 | 100 | 83 | 67 | 53 |
BTU/m | 624 | 583 | 557 | 408 | 345 | 287 | 231 | 180 |
BTU/ft | 189 | 177 | 169 | 124 | 105 | 87 | 70 | 55 |
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 144 | 135 | 129 | 94 | 80 | 66 | 53 | 42 |
BTU/m | 488 | 448 | 436 | 319 | 270 | 224 | 181 | 141 |
BTU/ft | 148 | 136 | 132 | 97 | 82 | 68 | 55 | 43 |
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 149 | 140 | 133 | 98 | 83 | 69 | 55 | 43 |
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 213 | 200 | 191 | 140 | 118 | 98 | 79 | 62 |
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 149 | 140 | 133 | 98 | 83 | 69 | 55 | 43 |
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 213 | 200 | 191 | 140 | 118 | 98 | 79 | 62 |
Boiler Temp | 75°C | dt50 (72°C flow) |
70°C | 60°C | 55°C | 50°C | 45°C | 40°C |
Watts/m | 267 | 250 | 238 | 175 | 148 | 123 | 99 | 78 |
TherMiser control systems are designed to provide precise remote control of ThermaSkirt heating system, to closely maintain the desired room temperature and timings, providing a completely discreet heating system. Low surface temperature control for additional safety, or wireless multi-room zone control for ease of installation are also available.
Download our free ThermaSkirt® Designer Software and follow the simple steps to install it on your system. After the installation is finished, launch the design software to create your own ThermaSkirt® heating system - in minutes! It will even work out your heat loss calculation, heat output, temperature drop & flow resistance!
ThermaSkirt® can be supplied in pre-cut ready-to-install room kits, complete with a numbered room plan. Your installer can follow the step-by-step instructions supplied.
Alternatively, you can buy full 2M, 3M and 6M lengths and cut on site. Ask about our on-site training day.
Full set of instructions are available and can be downloaded from the Technical Information section of our website.